papers AI Learner
The Github is limit! Click to go to the new site.

First result of the experimental search for the 2K-capture of Xe-124 with the copper proportional counter

2014-04-22
Yu.M. Gavrilyuk, A.M. Gangapshev, V.V. Kazalov, V.V. Kuzminov, S.I. Panasenko, S.S. Ratkevich, D.A. Tekueva, S.P. Yakimenko

Abstract

First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with regard to 2K(2\nu)-capture for the ground state of Te-124 has been found: T_{1/2} > 4.67x10^{20} y (90% C.L.). A sample with volume 52 L comprising of Xe-124 (10.6 L - 58.6 g) and Xe-126 (14.1 L - 79.3 g) will used at the next step of the experiment to increase a sensitivity of 2K-caption of Xe-124 registration. In this case sensitivity to the investigated process will be at the level of S=1.46 x 10^{21} y (90% C.L.) for 1 year measurement.

Abstract (translated by Google)

给出了用大容量铜正比计数器搜索Xe-124的2K捕获实验的初步结果。测量中使用具有63.3%(44g)Xe-124的12升样品。已经发现对于Te-124的基态的2K(2’) - 捕获的Xe-124的半衰期的限制已经被发现:T_ {1/2}> 4.67x10 ^ {20} y(90 %CL)。在实验的下一个步骤中使用包含Xe-124(10.6L-58.6g)和Xe-126(14.1L-79.3g)的体积52L的样品以增加Xe-124的2K-标题的灵敏度注册。在这种情况下,对被调查过程的敏感度将在S = 1.46×10 ^ {21} y(90%C.L.)的水平下进行1年的测量。

URL

https://arxiv.org/abs/1404.5530

PDF

https://arxiv.org/pdf/1404.5530


Similar Posts

Comments